Description
GlutenDetect
Urine
Description
Test system designed to detect gluten immunogenic peptides (GIP) in urine specimens. The test consists of a lateral flow device, a tube containing a conditioning solution, a disposable plastic syringe and a quick start guide with instructions for use.
How to use
Collect a urine sample and 2 ml of the sample, using the included disposable plastic syringe, is transferred to the tube containing the conditioning solution. Close the tube tightly and shake gently for 5-10 seconds to allow the urine to mix with the conditioning solution. After removing the lateral flow device from its packaging, add 4 drops of solution from the tube to the S-zone area by unscrewing the transparent cap of the tube.
Leave for 15 minutes at room temperature, and read the device:
- Negative : A single green line (control line) appears in the central part of the device (control zone).
- Positive : In addition to the green line, a red line (test line) appears in the test region.
- Invalid : If the green line does not appear, regardless of the red line that appears, the test is considered invalid and must be repeated.
Format
Kit containing:
-a test tube containing a conditioning solution
-a disposable plastic syringe
-a quick guide with instructions for use.
Format
Package containing 1 test.
Code KT-6414
Test system designed to detect gluten immunogenic peptides (GIP) in urine specimens. The test consists of a lateral flow device, a tube containing a conditioning solution, a disposable plastic syringe and a quick start guide with instructions for use.
How to use
Collect a urine sample and 2 ml of the sample, using the included disposable plastic syringe, is transferred to the tube containing the conditioning solution. Close the tube tightly and shake gently for 5-10 seconds to allow the urine to mix with the conditioning solution. After removing the lateral flow device from its packaging, add 4 drops of solution from the tube to the S-zone area by unscrewing the transparent cap of the tube.
Leave for 15 minutes at room temperature, and read the device:
- Negative : A single green line (control line) appears in the central part of the device (control zone).
- Positive : In addition to the green line, a red line (test line) appears in the test region.
- Invalid : If the green line does not appear, regardless of the red line that appears, the test is considered invalid and must be repeated.
Format
Kit containing:
-a test tube containing a conditioning solution
-a disposable plastic syringe
-a quick guide with instructions for use.
Format
Package containing 1 test.
Code KT-6414