Spacer chamber for pre-dosed spray dispensers l'espace 220 ml for adults with mouthpiece inhalation valve 2 exhalation valves color code magenta

Save 27%
SKU: 905727350

Price:
Sale price€22,54 Regular price€30,90
Stock:
37 - In stock

Pagamenti sicuri Apple Pay Google Pay Maestro Mastercard PayPal Shop Pay Visa

Description

The space

Description
Spacer chamber for pre-dosed sprays.
The use of the spacer chamber is recommended by the international guidelines for the correct treatment of asthma.
The spacer is recommended for adequate deposition of the drug in the lower airways, since the direct use of the inhaler, given the high speed of the drug exiting, would cause the concentration of nebulized drug in the oropharynx.
The space helps limit the side effects of oropharyngeal deposition of the drug and facilitates coordination between the act of inspiration and the delivery with the metered-dose spray.
Espace simplifies therapy and ensures more effective treatment with all metered dose inhalers thanks to adequate diffusion of the nebulized drug in the lower airways.
Conical shape whose flow dynamics makes a greater fraction of drug available, increasing deposition in the lower airways.
Ideal volume: The space reduces the re-aggregation of nebulized drug particles thanks to the specifically designed volume.
Lamellar bottom: The space is equipped with variable opening lamellae that adapt to the force of the patient's inspiratory act, facilitating therapy.
Anatomical and ergonomic mask that facilitates compliance even for the smallest. Excellent adherence with minimal pressure.
Valve system: the colored valve is a valid aid for the visual control of respiratory acts. The movement is clearly visible: it allows a correct coordination between the delivery of the drug and the inspiration and allows to count the respiratory acts.
Universal fitting base for all MDI (Metered Dose Inhalers) pre-dosed sprays. All models can be sterilized at 121°C. Low electrostatic charges. Fabric bag for better hygiene and safer transport. Durable and robust materials.
Latex free.

How to use
1 - Before use, carefully examine the product to ensure that it is assembled correctly and that there are no foreign objects or missing components. Remove any foreign objects before use;
2 - Before use, read the instructions supplied with the MDI. Remove the cover from the MDI;
3 - introduce the MDI into the bottom;
4 - put the mouthpiece in your mouth and hold it between your lips;
5 - press the MDI and inhale slowly through the mouth. Keep the mouthpiece in the mouth with the lips tightly closed for at least 5 breaths after pressing the inhaler. During inhalation, air enters from the openings at the bottom, which facilitates inhalation of the nebulizer. The exhaled air exits through the exhalation valve;
6 - wait 30 seconds before administering another dose of medicine (repeat steps 4-5), or as directed by your doctor. Administer only one puff of medicine at a time and follow your doctor's dosing instructions.

Cleaning
if the device is always used by the same person, clean it as indicated. If the device is used by more than one person, in addition to cleaning, it is necessary to sterilize it in an autoclave at 121°C for 15 minutes after each use. The device can be sterilized without compromising its functional characteristics up to 20 times, after which it must be replaced. If deemed appropriate, for a thorough cleaning, it is possible to boil the device or wash it in the dishwasher.
A - the product should be cleaned following the instructions below before first use and then at least once a week: remove foundation and mask;
B - leave the parts to soak for 15 minutes in warm water with a neutral detergent with disinfectant action. Shake gently;
C - rinse in clean water;
D - Shake off excess water as shown. Do not use dry cloths to dry the device parts. Make sure the parts are dry before reassembling;
E - Replace the bottom and mask when the parts are completely dry and ready for use. Center the alignment arrow on the back component with the alignment notch on the body as shown.

Warnings
Replace the product if there is a damaged component. Some components due to their size could be swallowed by children. Do not leave these components unattended. The presence of an adult is always necessary. Do not disassemble the product beyond what is indicated in the cleaning instructions. If you have any doubts about the use of the product, consult your doctor or pharmacist. Clean the product only as indicated in these instructions to ensure its effective functioning.

Conservation
When not in use, store the product in a clean container.
Replace the product after 24 months of continuous use.

Format
1 piece.

Code 471350

Payments and Security

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

You may also be interested in

Subscribe to our NEWSLETTER

an EXTRA discount for you right now !!