Description

flowbreathe
smart aerosol

It is a medical device for home use for nebulizing and administering drugs and solutions prescribed or recommended by the doctor.
Fluirespira Smart Aerosol is a system for treating the laryngotracheal tract up to the alveolar areas with the aid of the Fluirespira nebulizer equipped with an advanced dual-speed delivery system and related accessories.

How to use
Before each use, wash your hands and clean the appliance as described in the instruction booklet.
During application, it is recommended to adequately protect yourself from any drips.
1. Insert the power cord into the socket and then connect it to an electrical outlet corresponding to the voltage of the appliance.
It must be positioned in such a way that it is not difficult to disconnect from the electrical network.
2. Insert the nozzle into the upper part by pressing as indicated by the 2 arrows in the “Connection diagram”. Insert the speed selector with valve into the upper part as indicated in the “Connection diagram”. Pour the medicine prescribed by the doctor into the lower part. Close the nebulizer by turning the upper part clockwise.
3. Connect the accessories as indicated in the “Connection diagram”.
4. Sit comfortably holding the nebulizer, place the mouthpiece on your mouth or use the nosepiece or mask. If you use the mask accessory, place it on your face (with or without the use of the elastic).
5. Turn on the device by pressing the switch and inhale and exhale deeply. It is recommended to hold your breath for a moment after inhaling so that the inhaled aerosol droplets can settle. Then exhale slowly.
6. Once the application is finished, turn off the appliance and unplug it.

Technical features
Model: P0611EM F400.
Power supply: 230 V ~ 50 Hz / 130 VA.
Maximum pressure: 1.8 ± 0.3 bar.
Air flow to compressor: 9 litres/min approx.
Noise level (at 1 meter): 54 dB (A) approx.
Operation: continuous.
Dimensions: 16 (w) x 19 (d) x 10 (h) cm.
Weight: 1,300 kg.
Temperature: minimum 10°C; maximum 40°C.
Air humidity: minimum 10%; maximum 95%.
Atmospheric pressure: minimum 69KPa; maximum 106KPa.

Warnings
The ampoule and accessories are for personal use only to avoid any risk of contagion infection.
Read the instructions carefully and keep them for future reference and use the appliance only as described in the manual.
Before first use, and periodically during the life of the product, check the integrity of the appliance structure and the power cable to ensure that there is no damage; if it is damaged, do not plug it in and take the product immediately to an authorised FLAEM service centre or to your trusted retailer.
The expected average life of the accessories is 1 year; however, it is advisable to replace the ampoule every 6 months in intensive use (or sooner if the ampoule is obstructed) to always guarantee maximum therapeutic efficacy.
In the presence of children and non-self-sufficient people, the appliance must be used under the strict supervision of an adult who has read the manual.
Some parts of the appliance are so small that they could be swallowed by children; therefore, keep the appliance out of the reach of children.
Do not use the pipes and cables supplied for purposes other than their intended use, they may cause a strangulation hazard, pay particular attention to children and people with particular difficulties, often these people are not able to correctly assess the dangers. This device is not suitable for use in the presence of a flammable anaesthetic mixture with air, or with oxygen or nitrous oxide.
Always keep the power cord away from hot surfaces.
Keep the power cord away from animals (e.g. rodents), otherwise such animals may damage the insulation of the power cord.
Do not handle the appliance with wet hands.
Do not use the appliance in humid environments (e.g. while bathing or showering).
Do not immerse the appliance in water; if this should accidentally happen, unplug it immediately.
Do not remove or touch the appliance while it is immersed in water; unplug it first.
Use the device only in dust-free environments, otherwise the therapy may be compromised.
The casing of the device is not protected against the penetration of liquids. Do not clean the device under running water or by immersion and keep it away from splashes of water or other liquids.
Do not expose the appliance to particularly extreme temperatures.
Do not place the appliance near heat sources, in sunlight or in excessively hot environments.
Do not obstruct or introduce objects into the filter and its relative seat in the appliance.
Never block the ventilation slots located on both sides of the appliance.
Always operate the appliance on a hard surface free from obstacles.
Check that there is nothing blocking the ventilation slots before each use.
Do not insert any objects into the ventilation slots.
Repairs must be carried out only by FLAEM authorised personnel. Unauthorised repairs will void the warranty and may represent a danger to the user.
The average expected life of the compressor is 400 hours.
Do not modify this appliance without the manufacturer's authorization.
The Manufacturer shall be held responsible for safety, reliability and performance only if:
a) the appliance is used in accordance with the instructions for use b) the electrical system of the environment in which the appliance is used is compliant with standards and complies with current legislation.
The manufacturer must be contacted to report problems and/or unexpected events relating to operation.
Interactions: The materials used in contact with drugs have been tested with a wide range of drugs. However, given the variety and continuous evolution of drugs, it is not possible to exclude interactions. It is recommended to consume the drug as soon as possible after opening and to avoid prolonged exposure to the ampoule.

Format
The package contains:
- aerosol device (main unit)
- connecting tube
- accessories: RF7 Dual Speed ​​nebulizer (lower part, nozzle, upper part, speed selector), mouthpiece, pediatric nasal, Soft Touch adult mask, Soft Touch pediatric mask.